{"id":11345,"date":"2021-07-12T14:00:51","date_gmt":"2021-07-12T12:00:51","guid":{"rendered":"https:\/\/cprbestek.com\/produit\/vrdc-sel-voltage-sensitive-relay-select\/"},"modified":"2025-03-13T18:37:07","modified_gmt":"2025-03-13T17:37:07","slug":"vrdc-sel-voltage-sensitive-relay-select","status":"publish","type":"product","link":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/","title":{"rendered":"VRDC SEL, A0402 Voltage Sensitive Relay Select"},"content":{"rendered":"<p>VRDC SEL ( A0402 ) has two power input terminals, TB1-1 is for 24VAC, TB1-2 is for 12 to 24VDC, TB1-3 is the power supply ground, both inputs use a half wave rectifier filter circuit to power the VRDC board. The VRDC has two LEDs the green indicates the VRDC is powered and the red indicated when the relay is energized. The VRDC\/SEL\u2019s input is on terminal 4 and the inputs common shares terminal 3. The dip switch\u2019s position 1 selects whether the time delay is applied to the relay energizing or de-energizing. Positions 2 thru 6 select the input range and type, only one input switch is to be selected at a time. The input ranges are P2 = 0-20mA, P3 = 0-5VDC, P4 = 0-15VDC, P5 = 0-30VDC and P6 = 0-60VDC.\u00a0from Atkinson Electronics<\/p>\n<p><a class=\"jce_file\" title=\"IEE 1201 (En)\" href=\"\/images\/stories\/PDF\/IEE\/IEE%201201_(En).pdf\" target=\"_blank\" rel=\"noopener\"> <img decoding=\"async\" class=\"jce_icon size-full wp-image-11340\" style=\"border: 0px; vertical-align: middle;\" title=\"pdf\" src=\"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/556479dcde9ad-pdf_small-alt.gif\" alt=\"alt\" width=\"16\" height=\"16\" \/><\/a>\u00a0<a href=\"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/VRDC_SEL-X_Voltage_Sensitive_Relay_Select_Data_Sheet_Atkinson_Electronics.pdf\">VRDC SEL-X Voltage Sensitive Relay Select Data Sheet Atkinson Electronics.pdf<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>VRDC SEL ( A0402 ) is an adjustable voltage relay for DC signal application. The VRDC \/SEL is used in applications where a varying DC voltage signal is used to switch a relay, such as in generator control circuit, a low battery voltage load disconnect, etc. The cut-in voltage and cut-out voltage and time delay values are set using the corresponding multi-turn potentiometers. Atkinson Electronics<\/p>\n","protected":false},"featured_media":11335,"template":"","meta":[],"product_brand":[],"product_cat":[66,146],"product_tag":[],"class_list":["post-11345","product","type-product","status-publish","has-post-thumbnail","product_cat-atkinson-electronics-en","product_cat-generator-start-control-module-en","pa_condition-new-en","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>VRDC SEL, A0402 Voltage Sensitive Relay Select - Specialized in temperature controls, automated systems and gas detection<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VRDC SEL, A0402 Voltage Sensitive Relay Select - Specialized in temperature controls, automated systems and gas detection\" \/>\n<meta property=\"og:description\" content=\"VRDC SEL ( A0402 ) is an adjustable voltage relay for DC signal application. The VRDC \/SEL is used in applications where a varying DC voltage signal is used to switch a relay, such as in generator control circuit, a low battery voltage load disconnect, etc. The cut-in voltage and cut-out voltage and time delay values are set using the corresponding multi-turn potentiometers. Atkinson Electronics\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/\" \/>\n<meta property=\"og:site_name\" content=\"Specialized in temperature controls, automated systems and gas detection\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-13T17:37:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1052\" \/>\n\t<meta property=\"og:image:height\" content=\"670\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/\",\"url\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/\",\"name\":\"VRDC SEL, A0402 Voltage Sensitive Relay Select - Specialized in temperature controls, automated systems and gas detection\",\"isPartOf\":{\"@id\":\"https:\/\/cprbestek.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg\",\"datePublished\":\"2021-07-12T12:00:51+00:00\",\"dateModified\":\"2025-03-13T17:37:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#primaryimage\",\"url\":\"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg\",\"contentUrl\":\"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg\",\"width\":1052,\"height\":670},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cprbestek.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Boutique\",\"item\":\"https:\/\/cprbestek.com\/boutique\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"VRDC SEL, A0402 Voltage Sensitive Relay Select\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cprbestek.com\/#website\",\"url\":\"https:\/\/cprbestek.com\/\",\"name\":\"Distributeur des contr\u00f4les de temp\u00e9rature et de d\u00e9tection de gaz\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cprbestek.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"VRDC SEL, A0402 Voltage Sensitive Relay Select - Specialized in temperature controls, automated systems and gas detection","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/","og_locale":"en_US","og_type":"article","og_title":"VRDC SEL, A0402 Voltage Sensitive Relay Select - Specialized in temperature controls, automated systems and gas detection","og_description":"VRDC SEL ( A0402 ) is an adjustable voltage relay for DC signal application. The VRDC \/SEL is used in applications where a varying DC voltage signal is used to switch a relay, such as in generator control circuit, a low battery voltage load disconnect, etc. The cut-in voltage and cut-out voltage and time delay values are set using the corresponding multi-turn potentiometers. Atkinson Electronics","og_url":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/","og_site_name":"Specialized in temperature controls, automated systems and gas detection","article_modified_time":"2025-03-13T17:37:07+00:00","og_image":[{"width":1052,"height":670,"url":"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/","url":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/","name":"VRDC SEL, A0402 Voltage Sensitive Relay Select - Specialized in temperature controls, automated systems and gas detection","isPartOf":{"@id":"https:\/\/cprbestek.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#primaryimage"},"image":{"@id":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#primaryimage"},"thumbnailUrl":"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg","datePublished":"2021-07-12T12:00:51+00:00","dateModified":"2025-03-13T17:37:07+00:00","breadcrumb":{"@id":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#primaryimage","url":"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg","contentUrl":"https:\/\/cprbestek.com\/wp-content\/uploads\/2021\/07\/1495-VRDC-SEL.jpg","width":1052,"height":670},{"@type":"BreadcrumbList","@id":"https:\/\/cprbestek.com\/en\/produit\/vrdc-sel-voltage-sensitive-relay-select\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cprbestek.com\/"},{"@type":"ListItem","position":2,"name":"Boutique","item":"https:\/\/cprbestek.com\/boutique\/"},{"@type":"ListItem","position":3,"name":"VRDC SEL, A0402 Voltage Sensitive Relay Select"}]},{"@type":"WebSite","@id":"https:\/\/cprbestek.com\/#website","url":"https:\/\/cprbestek.com\/","name":"Distributeur des contr\u00f4les de temp\u00e9rature et de d\u00e9tection de gaz","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cprbestek.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/product\/11345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/media\/11335"}],"wp:attachment":[{"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/media?parent=11345"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/product_brand?post=11345"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/product_cat?post=11345"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cprbestek.com\/en\/wp-json\/wp\/v2\/product_tag?post=11345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}